Relationship Between Place Sanitation, Equipment Sanitation And Handling Hygiene With Coliform Bacteria At Drinking Water Depot In Sukmajaya District

Main Article Content

Librianti Virdha Amartya
Joko Tri
Dewanti Nikie Astorina Yunita

Abstract

The increasing need for drinking water consumption has caused drinking water depots (DAM) to become one of the most popular choices among people. This is because the number of drinking water depots in Sukmajaya District has increased from 2019-2020 by 33%. To acquire consumption-safe status, DAM’s water must be free from coliforms. This study aims to determine the relationship between DAM’s sanitation hygiene with the number of Coliforms, with DAM in Sukmajaya District as the research subject. This study uses an analytical observational method using a cross-sectional approach. The research variables are place sanitation, equipment sanitation, and handler hygiene from the research population of 45 DAM units, with 31 DAM units taken as samples. By observation and interview with checklist sheets guided by the Minister of Health Regulation No. 43 of 2014, the results showed that among 31 DAMs, there were 15 (48.4%) DAMs that met the requirements for the total number of Coliforms, and 16 (51.6%) others did not meet the requirements for the total number of Coliforms. The results showed that there was a significant relationship between equipment sanitation (p = 0.001)  and the hygienic conditions of the handlers (p = 0.001) in the presence of Coliform bacteria. Meanwhile, in the sanitation conditions (p=0.537) there was no significant relationship with the presence of Coliform bacteria. It can be concluded that there is a significant relationship between equipment sanitation and handler hygiene and the number of coliforms in DAM waters. Conversely, the place sanitation variable shows that there is no significant relationship with the number of Coliforms in DAM waters.

Article Details

Section
Articles
Author Biographies

Librianti Virdha Amartya, Diponegoro University

   

Joko Tri, Bagian Kesehatan Lingkungan, Fakultas Kesehatan Masyarakat Universitas Diponegoro

     

Dewanti Nikie Astorina Yunita, Bagian Kesehatan Lingkungan, Fakultas Kesehatan Masyarakat Universitas Diponegoro

   

References

Walangitan MR, Sapulete M, Pangemanan J. Gambaran Kualitas Air Minum dari Depot Air Minum Isi Ulang di Kelurahan Ranotana-Weru dan Kelurahan Karombasan Selatan Menurut Parameter Mikrobiologi. J Kedokt Komunitas dan Trop. 2016;4(1).

Trisnaini I, Sunarsih E, Septiawati D. Analisis Faktor Risiko Kualitas Bakteriologis Air Minum Isi Ulang Di Kabupaten Ogan Ilir. J Ilmu Kesehat Masy. 2018;9(1):28–40.

Marselinus Yunior Nisanson. Kualitas Air Isi Ulang pada Depot Air Minum di Wilayah Utara Kota Ende. Teknosiar [Internet]. 2015;9(2 SE-):29–34. Available from: http://www.uniflor.ac.id/e-journal/index.php/TEKNOSIAR/article/view/193

Pakpahan RS, Picauly I, Mahayasa INW. Cemaran Mikroba Escherichia coli dan Total Bakteri Koliform pada Air Minum Isi Ulang. Kesmas Natl Public Heal J. 2015;9(4):300.

Natalia LA, Harninabintari S, Mustikaningtyas D. Kajian Kualitas Bakteriologis Air Minum Isi Ulang Di Kabupaten Blora. Unnes J Life Sci. 2014;3(1):31–8.

Rosita N. Analisis Kualitas Air Minum Isi Ulang Beberapa Depot Air Minum Isi Ulang (DAMIU) di Tangerang Selatan. J Kim Val. 2014;4(2):134–41.

Badan Pusat Statistik Kota Depok. Statistic Daerah Kota Depok Tahun 2019. Depok; 2019.

Mirza MN. Hygiene Sanitasi Dan Jumlah Coliform Air Minum. KEMAS J Kesehat Masy. 2014;9(2):167–73.

Kemenkes RI. Peraturan Menteri Kesehatan No. 43 tentang Higiene Sanitasi Depot Air Minum. Indonesia; 2014.

Dilapanga MR, Joseph WBS, Loho H, Masyarakat FK, Sam U, Manado R. Higiene Sanitasi dan Kualitas Bakteriologis Air Minum pada Depot Air Minum Isi Ulang (DAMIU) di Kecamatan Sario Kota Manado Tahun 2014. J Media Kesehat. 2014;3(1):1–8.

Abdilanov D, Hasan W, Marsaulina I. Pelaksanaan Penyelenggaraan Higiene Sanitasi dan Pemeriksaan Kualitas Air Minum pada Depot Air Minum Isi Ulang di Kota Padang Tahun 2012. J Lingkung dan Keselam Kerja. 2012;4(53):1–8.

Jayadisastra. Hubungan Pengetahuan, Kebiasaan, dan Keberadaan Bakteriologis E.coli dalam Air Minum Isi Ulang yang Berkunjung ke Puskesmas Ciputat Tahun 2013. UIN Syarif Hidayatullah; 2013.

Mila W, Nabilah SL, Puspikawati SI. Higiene dan Sanitasi Depot Air Minum Isi Ulang di Kecamatan Banyuwangi Kabupaten Banyuwangi Jawa Timur : Kajian Deskriptif. J Ikesma. 2020;16(1):7.

Putra I, Ikhtiar M, Emelda A. Analisis Mikroorganisme Udara terhadap Gangguan Kesehatan dalam Ruangan Administrasi Gedung Menara UMI Makassar. J Kesehat. 2018;1(2):68–75.

Maulana HDJ. Promosi Kesehatan. 2007. 112–113 p.

Atari M, Pramadita S, Sulastri A. Pengaruh Higiene Sanitasi terhadap Jumlah Bakteri Coliform dalam Air Minum Isi Ulang di Kecamatan Pontianak Kota. J Rekayasa Lingkung Trop. 2020;4(1):1–10.

Fathoni A. Identifikasi Bakteri Esherehia Coli pada AMIU yang diproduksi DAMIU di kecamatan Padang Selatan. Artik Penelit. 2015;4(2).

Birawida AB, Selomo M, Mallongi A. Potential hazards from hygiene, sanitation and bacterium of refill drinking water at Barrang Lompo island (water and food safety perspective). IOP Conf Ser Earth Environ Sci. 2018;157(1).

Sulatri NL, Yogeswara IBA, Nursini NW. Efektifitas Sinar Ultraviolet terhadap Cemaran Bakteri Patogen pada Makanan Cair Sonde untuk Pasien Immune-Compremissed. J Gizi Indones (The Indones J Nutr. 2017;5(2):112–8.

Badun A. The Relationship of Drinking Water Depot Sanitation with the Presence of Coliform and Eschericia Coli. MIRACLE J Public Heal. 2021;4(2):187–94.

Kasim KP, Setiani O, W NE. Faktor-Faktor yang Berhubungan dengan Cemaran Mikroba dalam Air Minum Isi Ulang pada Depot Air Minum Kota Makassar. J Kesehat Lingkung Indones. 2016;13(2):39–44.

Marpaung MDO, Marsono BD. Uji Kualitas Air Minum Isi Ulang di Kecamatan Sukolilo Surabaya Ditinjau dari Perilaku dan Pemeliharaan Alat. J Tek POMITS. 2013;2(2):2–6.

Setyorini E. Hubungan Praktek Higiene Pedagang Dengan Keberadaan Eschericia Coli Pada Rujak Yang Di Jual Di Sekitar Kampus Universitas Negeri Semarang. Unnes J Public Heal. 2014;2(3):1–8.

Yamistada G, Fahri S, Sari JN. Study Hygiene Operator dan Sanitasi Terhadap Kualitas Bakteriologis Air Minum Isi Ulang di Kota Jambi. J Poltekkes Jambi. 2016;011(651):243–7.

Sofiyanto HO, Joko T, Wahyuningsih NE. Hubungan Sanitasi Lingkungan, Personal Higienen dengan Jumlah Bakteri Escherichia coli pada DAMIU di Kawasan Universitas Diponegoro Tembalang. J Kesehat Masy. 2016;4(4):32–952.